Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chim Acta ; 980: 41-49, 2017 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-28622802

RESUMO

Forensic DNA analysis requires several steps, including DNA extraction, PCR amplification, and separation of PCR fragments. Intuitively, there are numerous situations where it would be beneficial to speed up the overall DNA analysis process; in this work, we focus on the most time-consuming component in the analysis pipeline, namely the polymerase chain reaction (PCR). Primers were specially designed to target 10 human genomic loci, all yielding amplicons shorter than 350 bases, for ease of downstream integration with on-board microchip electrophoresis. Primer concentrations were adjusted specifically for microdevice amplification, resulting in well-balanced short tandem repeat (STR) profiles. Furthermore, studies were performed to push the limits of the DNA polymerase to achieve rapid, multiplexed PCR on various substrates, including transparent and black polyethylene terephthalate (Pe), and with two distinct adhesives, toner and heat sensitive adhesive (HSA). Rapid STR-based multiplexed PCR amplification is demonstrated in 15 min on a Pe microdevice using a custom-built system for fluid flow control and thermocycling for the full 10-plex, and in 10 min for a smaller multiplex consisting of six core CODIS loci plus Amelogenin with amplicons shorter than 200bp. Lastly, preliminary studies indicate the capability of this PCR microdevice platform to be integrated with both upstream DNA extraction, and downstream microchip electrophoresis. This, coupled to the use of reagents that are compatible with lyophilization (lyo-compatible) for PCR, represents the potential for a fully integrated rotationally-driven microdevice for complete forensic DNA analysis.


Assuntos
Eletroforese em Microchip , Genética Forense , Repetições de Microssatélites , Técnicas de Amplificação de Ácido Nucleico , DNA , Humanos , Reação em Cadeia da Polimerase
2.
Analyst ; 142(2): 366-374, 2017 01 16.
Artigo em Inglês | MEDLINE | ID: mdl-27990512

RESUMO

Warfarin, a commonly prescribed oral anticoagulant, is burdened by a narrow therapeutic index and high inter-individual variability in response, making it the second leading cause of drug-related emergency room visits. Since genetic factors contribute significantly to warfarin sensitivity, a genotype-guided dosing strategy may reduce the occurrence of adverse events. While numerous methods have been demonstrated for warfarin genotyping, the specifications of most assays with respect to turnaround time and cost are not ideal for routine testing. Here, we present a unique method for warfarin genotyping based on multiplex PCR coupled with Hybridization-induced Aggregation (HIA), a bead-based technique for sequence-specific detection. A multiplex allele-specific PCR reaction was used to generate products corresponding to 3 genetic variants associated with warfarin sensitivity [CYP2C9 *2, CYP2C9 *3, and VKORC1 (1173C>T)] and an internal control product. The products were detected simultaneously on a poly(ethylene terephthalate) (PeT) microdevice using HIA, which provided genotyping results in approximately 15 minutes following PCR. The genotyping results of 23 patient DNA samples using this approach were in 100% concordance with the results of a validated test (WARFGENO test, ARUP laboratories). Additionally, the PCR reaction was successfully transferred to a PeT chip, which provided accurate genotyping results from patient DNA samples in under an hour. This work demonstrates a simple, rapid, and affordable approach to warfarin genotyping based on multiplex allele-specific PCR coupled with HIA detection. By demonstrating both chemistries on PeT microdevices, we show the potential for integration on a single device for sample-to-answer genotyping.


Assuntos
Técnicas de Genotipagem/métodos , Polietilenotereftalatos/química , Varfarina/administração & dosagem , Citocromo P-450 CYP2C9/genética , Sondas de DNA/genética , Genótipo , Humanos , Reação em Cadeia da Polimerase Multiplex/métodos , Mutação , Hibridização de Ácido Nucleico , Vitamina K Epóxido Redutases/genética
3.
Lab Chip ; 16(23): 4569-4580, 2016 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-27766331

RESUMO

Current conventional methods utilized for forensic DNA analysis are time consuming and labor-intensive requiring large and expensive equipment and instrumentation. While more portable Rapid DNA systems have been developed, introducing them to a working laboratory still necessitates a high cost of initiation followed by the recurrent cost of the devices. This has highlighted the need for an inexpensive, rapid and portable DNA analysis tool for human identification in a forensic setting. In order for an integrated DNA analysis system such as this to be realized, device operations must always be concluded by a rapid separation of short-tandem repeat (STR) DNA fragments. Contributing to this, we report the development of a unique, multi-level, centrifugal microdevice that can perform both reagent loading and DNA separation. The fabrication protocol was inspired by the print, cut and laminate (PCL) technique described previously by our group, and in accordance, offers a rapid and inexpensive option compared with existing approaches. The device comprises multiple polyester-toner fluidic layers, a cyclic olefin copolymer separation domain and integrated gold leaf electrodes. All materials are commercially-available and complement the PCL process in a way that permits fabrication of increasingly sought after single-use devices. All reagents, including a viscous sieving matrix, are loaded centrifugally, eliminating external pneumatic pumping, and the sample is separated in <5 minutes using an effective separation length of only 4 cm (reagent loading to completed separation, is <37 minutes). The protocol for gold leaf electrode manufacture yielded up to 30 electrodes for less than $3 (cost of a 79 mm × 79 mm gold leaf sheet) and when using a device combining these electrodes and centrifugal reagent/polymer loading, the electrophoretic separation of STR fragments with two base resolution was demonstrated. This exemplary performance makes the device an ideal candidate for further integration and development of an inexpensive, portable and rapid forensic human identification system.


Assuntos
Centrifugação/instrumentação , DNA/isolamento & purificação , Eletroforese/instrumentação , Ouro , Dispositivos Lab-On-A-Chip , Eletrodos , Desenho de Equipamento , Fatores de Tempo
4.
Analyst ; 141(19): 5637-45, 2016 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-27460478

RESUMO

Pathogen detection has traditionally been accomplished by utilizing methods such as cell culture, immunoassays, and nucleic acid amplification tests; however, these methods are not easily implemented in resource-limited settings because special equipment for detection and thermal cycling is often required. In this study, we present a magnetic bead aggregation assay coupled to an inexpensive microfluidic fabrication technique that allows for cell phone detection and analysis of a notable pathogen in less than one hour. Detection is achieved through the use of a custom-built system that allows for fluid flow control via centrifugal force, as well as manipulation of magnetic beads with an adjustable rotating magnetic field. Cell phone image capture and analysis is housed in a 3D-printed case with LED backlighting and a lid-mounted Android phone. A custom-written application (app.) is employed to interrogate images for the extent of aggregation present following loop-mediated isothermal amplification (LAMP) coupled to product-inhibited bead aggregation (PiBA) for detection of target sequences. Clostridium difficile is a pathogen of increasing interest due to its causative role in intestinal infections following antibiotic treatment, and was therefore chosen as the pathogen of interest in the present study to demonstrate the rapid, cost-effective, and sequence-specific detection capabilities of the microfluidic platform described herein.

5.
Analyst ; 141(15): 4667-75, 2016 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-27250903

RESUMO

To date, the forensic community regards solid phase extraction (SPE) as the most effective methodology for the purification of DNA for use in short tandem repeat (STR) polymerase chain reaction (PCR) amplification. While a dominant methodology, SPE protocols generally necessitate the use of PCR inhibitors (guanidine, IPA) and, in addition, can demand timescales of up to 30 min due to the necessary load, wash and elution steps. The recent discovery and characterization of the EA1 protease has allowed the user to enzymatically extract (not purify) DNA, dramatically simplifying the task of producing a PCR-ready template. Despite this, this procedure has yet to make a significant impact on microfluidic technologies. Here, we describe a microfluidic device that implements the EA1 enzyme for DNA extraction by incorporating it into a hybrid microdevice comprising laminated polyester (Pe) and PMMA layers. The PMMA layer provides a macro-to-micro interface for introducing the biological sample into the microfluidic architecture, whilst also possessing the necessary dimensions to function as the swab acceptor. Pre-loaded reagents are then introduced to the swab chamber centrifugally, initiating DNA extraction at 75 °C. The extraction of DNA occurs in timescales of less than 3 min and any external hardware associated with the transportation of reagents by pneumatic pumping is eliminated. Finally, multiplexing is demonstrated with a circular device containing eight separate chambers for the simultaneous processing of eight buccal swab samples. The studies here provide DNA concentrations up to 10 ng µL(-1) with a 100% success rate in less than 3 minutes. The STR profiles generated using these extracted samples demonstrate that the DNA is of PCR forensic-quality and adequate for human identification.


Assuntos
DNA/isolamento & purificação , Enzimas , Técnicas Analíticas Microfluídicas , Polimetil Metacrilato , Humanos , Poliésteres , Reação em Cadeia da Polimerase
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...